STEPTEST

NAME
SYNOPSIS
FUNCTIONS
PINS
PARAMETERS
LICENSE

NAME

steptest − Used by Stepconf to allow testing of acceleration and velocity values for an axis.

SYNOPSIS

loadrt steptest [count=N|names=name1[,name2...]]

FUNCTIONS

steptest.N (requires a floating-point thread)

PINS

steptest.N.jog-minus bit in

Drive TRUE to jog the axis in its minus direction

steptest.N.jog-plus bit in

Drive TRUE to jog the axis in its positive direction

steptest.N.run bit in

Drive TRUE to run the axis near its current position_fb with a trapezoidal velocity profile

steptest.N.maxvel float in

Maximum velocity

steptest.N.maxaccel float in

Permitted Acceleration

steptest.N.amplitude float in

Approximate amplitude of positions to command during ’run’

steptest.N.dir s32 in

Direction from central point to test: 0 = both, 1 = positive, 2 = negative

steptest.N.position-cmd float out
steptest.
N.position-fb float in
steptest.
N.running bit out
steptest.
N.run-target float out
steptest.
N.run-start float out
steptest.
N.run-low float out
steptest.
N.run-high float out
steptest.
N.pause s32 in (default: 0)

pause time for each end of run in seconds

PARAMETERS

steptest.N.epsilon float rw (default: .001)
steptest.
N.elapsed float r

Current value of the internal timer

LICENSE

GPL