freqgen − software step pulse generation OBSOLETE - see stepgen’s ’ctrl_type=v’ option. |
loadrt freqgen step_type=type0[,type1...] |
freqgen is used to control stepper motors. The maximum step rate depends on the CPU and other factors, and is usually in the range of 10KHz to 50KHz. If higher rates are needed, a hardware step generator is a better choice. freqgen runs the motor at a commanded velocity, subject to acceleration and velocity limits. It does not directly control position. freqgen can control a maximum of eight motors. The number of motors/channels actually loaded depends on the number of type values given. The value of each type determines the outputs for that channel. freqgen supports 15 possible step types. By far the most common step type is ’0’, standard step and direction. Others include up/down, quadrature, and a wide variety of three, four, and five phase patterns that can be used to directly control some types of motor windings. (When used with appropriate buffers of course.) Some of the stepping types are described below, but for more details (including timing diagrams) see the stepgen section of the HAL reference manual. |
type 0: step/dir |
Two pins, one for step and one for direction. make-pulses must run at least twice for each step (once to set the step pin true, once to clear it). This limits the maximum step rate to half (or less) of the rate that can be reached by types 2-14. The parameters steplen and stepspace can further lower the maximum step rate. Parameters dirsetup and dirhold also apply to this step type. |
type 1: up/down |
Two pins, one for ’step up’ and one for ’step down’. Like type 0, make-pulses must run twice per step, which limits the maximum speed. |
type 2: quadrature |
Two pins, phase-A and phase-B. For forward motion, A leads B. Can advance by one step every time make-pulses runs. |
type 3: three phase, full step |
Three pins, phase-A, phase-B, and phase-C. Three steps per full cycle, then repeats. Only one phase is high at a time - for forward motion the pattern is A, then B, then C, then A again. |
type 4: three phase, half step |
Three pins, phases A through C. Six steps per full cycle. First A is high alone, then A and B together, then B alone, then B and C together, etc. |
types 5 through 8: four phase, full step |
Four pins, phases A through D. Four steps per full cycle. Types 5 and 6 are suitable for use with unipolar steppers, where power is applied to the center tap of each winding, and four open-collector transistors drive the ends. Types 7 and 8 are suitable for bipolar steppers, driven by two H-bridges. |
types 9 and 10: four phase, half step |
Four pins, phases A through D. Eight steps per full cycle. Type 9 is suitable for unipolar drive, and type 10 for bipolar drive. |
types 11 and 12: five phase, full step |
Five pins, phases A through E. Five steps per full cycle. See HAL reference manual for the patterns. |
types 13 and 14: five phase, half step |
Five pins, phases A through E. Ten steps per full cycle. See HAL reference manual for the patterns. |
freqgen.make-pulses (no floating-point) |
Generates the step pulses, using information computed by update-freq. Must be called as frequently as possible, to maximize the attainable step rate and minimize jitter. Operates on all channels at once. |
freqgen.capture-position (uses floating point) |
Captures position feedback value from the high speed code and makes it available on a pin for use elsewhere in the system. Operates on all channels at once. |
freqgen.update-freq (uses floating point) |
Accepts a velocity command and converts it into a form usable by make-pulses for step generation. Operates on all channels at once. |
freqgen.N.counts s32 out |
The current position, in counts, for channel N. Updated by capture-position. |
freqgen.N.position-fb float out |
The current position, in length units (see parameter position-scale). Updated by capture-position. |
freqgen.N.velocity float in (freqgen only) |
Commanded velocity, in length units per second (see parameter velocity-scale). |
freqgen.N.step bit out (step type 0 only) |
Step pulse output. |
freqgen.N.dir bit out (step type 0 only) |
Direction output: low for forward, high for reverse. |
freqgen.N.up bit out (step type 1 only) |
Count up output, pulses for forward steps. |
freqgen.N.down bit out (step type 1 only) |
Count down output, pulses for reverse steps. |
freqgen.N.phase-A thru phase-E bit out (step types 2-14 only) |
Output bits. phase-A and phase-B are present for step types 2-14, phase-C for types 3-14, phase-D for types 5-14, and phase-E for types 11-14. Behavior depends on selected stepping type. |
freqgen.N.frequency float ro |
The current step rate, in steps per second, for channel N. |
freqgen.N.maxaccel float rw |
The acceleration/deceleration limit, in steps per second squared. |
freqgen.N.maxfreq float rw (freqgen only) |
The maximum allowable velocity, in steps per second. If the requested maximum velocity cannot be reached with the current make-pulses thread period, it will be reset to the highest attainable value. |
freqgen.N.position-scale float rw |
The scaling for position feedback, in steps per length unit. |
freqgen.N.velocity-scale float rw |
The scaling for the velocity command, in steps per length unit. |
freqgen.N.rawcounts s32 ro |
The position in counts, as updated by make-pulses. (Note: this is updated more frequently than the counts pin.) |
freqgen.N.steplen u32 rw (step type 0 only) |
The length of the step pulses, in make-pulses periods. Measured from rising edge to falling edge. |
freqgen.N.stepspace u32 rw (step type 0 only) |
The minimum space between step pulses, in make-pulses periods. Measured from falling edge to rising edge. The actual time depends on the step rate and can be much longer. |
freqgen.N.dirsetup u32 rw (step type 0 only) |
The minimum setup time from direction to step, in make-pulses periods. Measured from change of direction to rising edge of step. |
freqgen.N.dirhold u32 rw (step type 0 only) |
The minimum hold time of direction after step, in make-pulses periods. Measured from falling edge of step to change of direction. |
freqgen should have an enable pin. freqgen’s command pin should be called velocity-cmd, not velocity, for clarity and consistency with stepgen. freqgen should use maxvel, not maxfreq. (In other words, the velocity limit should be scaled in length units per second, not steps per second. The scale parameter can be set to 1.0 if it is desired to work in steps instead of length units.) freqgen’s maxaccel parameter should be in length units per second squared, not steps per second squared, for consistency with stepgen. freqgen should use position-scale for scaling both command and feedback, velocity-scale is redundant and should be eliminated. Step type 1 (up/down) should respect the steplen and stepspace limits. Timing parameters steplen, stepspace, dirsetup, and dirhold should be in nano-seconds, not make-pulses periods. That would allow the period to be changed without requiring the parameters to be recalculated. All of these bugs have been fixed in stepgen. Only stepgen will continue to be maintained, since freqgen contains large amounts of code that duplicates code in stepgen. Since stepgen can provide the same functionality, there is no reason to maintain the duplicate code. freqgen may be eliminated at any time, and almost certainly will be eliminated for the version 2.2 release of EMC. |
stepgen(9) |